<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-11 02-04-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.80 MHz 5/5, 53 dBuV P2 SR
Pilot RDS Phase Difference
7.3 kHz 5.8 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 28 kHz 19118 0,0052
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-4,1 dBr -3,00 dBr -1,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P2 SR " E402 14 (Classics) 0 1 1 9 1:04, 11.12.2024
RT
"Notturno "
AF EON
91.7, 93.6, 94.5, 97.5 MHz E224, E201, E203
FM Scope Max at: 28 kHz MIN: 15 kHz % above 76 kHz: 0,0052 Acquired: 2024/12/11 2.03.36 Total samples: 19118 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: -1,7 dBr MIN: -4,1 dBr AVE: -3,00 dBr % above 12,2 dBr: 0,0 Last value: -3,2 dBr (2024/12/11 2.03.36) 01.50 01.52 01.54 01.56 01.58 02.00 02.02 0 50 100 Dev. MAX [kHz] -4 -2 0 Pm [dBr]